<LOGO>
FM Transmitter Measurement Report
Created: 2024-05-01 14-33-06
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 60 dBuV EUROPE 1
Pilot RDS Phase Difference
0.0 kHz 4.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
3 kHz 72 kHz 17078 0,0059
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
1,7 dBr 4,36 dBr 5,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"EUROPE 1" F213 0 (No PTY) 1 0 1 1 14:33, 1.05.2024
RT
"14H-15H HONDELATTE RACONTE - CORNEILLE, ENVERS ET CONTRE TOUT "
AF EON
89.5, 93.2, 93.3, 94.2, 99.0, 99.4, 102.5, 104.5, 104.6, 104.7, 106.5, 107.0 MHz -
FM Scope Station: 104.60 MHz, signal: 5/5 (60 dBuV) Max at: 72 kHz MIN: 3 kHz % above 75 kHz: 0,0059 Acquired: 2024/05/01 14:32:03 Total samples: 17078 Equivalent time: 0:14:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 5,4 dBr MIN: 1,7 dBr AVE: 4,36 dBr % above 10,2 dBr: 0,0 Last value: 4,9 dBr (2024/05/01 14:32:02) Station: 104.60 MHz, signal: 5/5 (60 dBuV) 14:20 14:22 14:24 14:26 14:28 14:30 14:32 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality